Eversion-based robots can enable safe access,steering and endoscopic imaging within the spinal subarachnoid space

Embodied AI and Robotics SDR Continuum Robotics RMIS
2026年07月21日
脊髓蛛网膜下腔内的安全导航受限于其狭窄、柔韧且极为脆弱的解剖结构。传统导管及连续体机器人依赖近端推力驱动,由此在器械与组织界面处产生摩擦力与剪切力,不仅制约远端操控精度,还显著增加神经损伤风险。本研究提出一种直径仅2毫米的外翻式生长型机器人平台,可在人体脊髓蛛网膜下腔内实现低摩擦的延伸与精准转向,并通过计算建模、仿体实验及完整人尸解剖标本研究对其性能进行了系统验证。该机器人集成了微型内窥镜,可实现实时鞘内可视化;其运动由压力驱动的远端外翻机制完成,将运动完全局限在末端,同时最大限度减少已部署主体部分的轴向滑动。仿体实验表明,相较于同等条件下采用推入式插入的对照组,该外翻式机器人平均相互作用力降低65.2%,峰值相互作用力降低48.0%。基于物理原理的建模分析进一步证实:外翻式生长机制可重新分布组织载荷,显著降低局部应力集中程度及界面剪切力,优于传统推入式插入方式。在完整人尸解剖标本中,该系统成功实现了150毫米的可控鞘内延伸,全程同步结合透视成像与内窥镜可视化,仅需标准腰椎穿刺入路即可覆盖多个椎体节段。术后行椎板切除术及硬脊膜切开术检查,未见硬脊膜或周围神经结构出现肉眼可见的宏观损伤。上述结果首次在完整人体脊柱解剖结构中,以力学表征为基础、并经多模态方法交叉验证,展示了外翻式机器人的鞘内导航能力,为未来鞘内介入治疗奠定了定量化的技术基础与标准化的操作范式。在推进临床转化前,尚需在更大样本量的人体解剖结构中开展进一步验证,并在生理条件下进行功能评估。
Safe navigation within the spinal subarachnoid space is constrained by its narrow, compliant, and delicate anatomy. Conventional catheters and continuum robots rely on proximal pushing, generating friction and shear along the tissue device interface that limit distal controllability and increase the risk of neural injury. Here, we present a 2 mm diameter eversion-growing robotic platform that enables friction minimised extension and steering within the human spinal subarachnoid space, validated through computational modelling, phantom experiments, and intact human cadaver studies. The robot integrates a miniature endoscope for real time intrathecal visualisation and advances by pressure driven tip eversion, localising motion to the distal tip while minimising translational sliding of the deployed body. Phantom experiments demonstrated reductions of 65.2% in mean interaction force and 48.0% in peak interaction force compared with matched push-based insertion. Physics based modelling showed that eversion based growth redistributed tissue loading, reducing local stress concentrations and interfacial shear relative to conventional insertion. In an intact human cadaver, the system achieved 150 mm of controlled intrathecal extension with concurrent fluoroscopic and endoscopic visualisation, providing access across multiple vertebral levels from a standard lumbar entry point. Postprocedural laminectomy and durotomy revealed no observable macroscopic disruption of the dura mater or surrounding neural structures. These results provide the first mechanically characterised and multimodally validated demonstration of eversion-based robotic navigation in intact human spinal anatomy, establishing a quantitative and procedural foundation for future intrathecal interventions. Further validation in larger anatomical cohorts and under physiological conditions will be required before clinical translation.
许愿